Other SIEMs
XplicitTrust events reach any SIEM or log platform that can receive syslog over TLS or an HTTPS webhook with a JSON body. This page says what such a receiver needs. It has no product click paths; for Wazuh and Microsoft Sentinel there are guides of their own.
In short
Use Syslog over TLS when the receiver has a TLS syslog input (RFC 5425, port 6514): rsyslog, syslog-ng, Splunk, Elastic / Logstash, Graylog, QRadar. Use the HTTPS webhook when it takes JSON over HTTP. Either way the receiver needs a certificate from a publicly trusted CA, must parse the JSON body, and should deduplicate on the event id.
What the receiver needs
Syslog over TLS (details):
- A TCP listener with TLS 1.2 or higher, by default on port 6514. The certificate must come from a publicly trusted CA and match the host name you enter in the forwarder; certificate verification cannot be turned off.
- RFC 5424 messages, each with the event as a JSON object in the
message body, whose single key
xplicittrustholds every event field. - Framing: Octet counting (RFC 5425), the default, for spec-compliant receivers. Receivers that treat TLS syslog as plain TCP syslog need Newline-delimited. See the table below.
- A message size limit of at least 64 KB. Most events are below 2 KB, but a configuration change with many changed fields or a network discovery summary with many hosts can be larger. rsyslog cuts messages off at 8 KB by default, and a cut-off message has invalid JSON.
HTTPS webhook (details):
- An HTTPS endpoint with a certificate from a publicly trusted CA that answers with any 2xx status within 10 seconds.
- A JSON body with
tenant_id,delivered_atand a batch of up to 500events[]. - Optionally, verification of the
X-Webhook-Signatureheader (sha256=<HMAC-SHA256 hex digest>of the raw body, with the forwarder's secret) and of anAuthorization: Bearertoken.
In both cases the receiver should deduplicate on the event id
(event_id), because delivery is at-least-once.
Compatibility
XplicitTrust sends RFC 5424 messages, by default with octet-counted framing (RFC 5425). Not every receiver supports that framing over TLS; for those, switch the forwarder to Newline-delimited.
| SIEM | Native Support | Notes |
|---|---|---|
| Splunk | Yes | TCP input with SSL; use Newline-delimited framing |
| Elastic / Logstash | Yes | tcp input with TLS; use Newline-delimited framing |
| Graylog | Yes | Syslog TCP input with TLS; use Newline-delimited framing |
| rsyslog | Yes | imtcp with TLS; octet-counted framing is supported out of the box |
| syslog-ng | Yes | syslog() source with transport(tls) |
| QRadar | Yes | TLS Syslog log source; switch to Newline-delimited framing if messages do not parse |
| Wazuh | No | Requires TLS termination and format conversion. See Wazuh for decoder and rules. |
| Microsoft Sentinel | No | Through the Azure Monitor Agent on a Linux log forwarder, with rsyslog terminating TLS. See Microsoft Sentinel for the parser and analytics rules. |
For receivers without TLS support, place a TLS termination proxy (e.g. stunnel) and, if needed, a format translator (e.g. rsyslog) in front of the receiver.
Steps
- Set up the receiver so that it accepts TLS (or HTTPS) on a public name with
a certificate from a publicly trusted CA. Check the certificate from
outside, for example with
openssl s_client -connect <name>:6514 -servername <name>: the verify return code must be0 (ok). - Add a forwarder in the Admin Console under Settings → SIEM → Event Forwarders; see Event forwarding. Choose the protocol and, for syslog, the framing from the table above.
- Leave Event Filters empty at first, so the heartbeats and every event type arrive.
- Send a test event.
Verify
Send a test event. One event_forwarder.test event arrives, with the event
id 0 and "test": true. Heartbeats (event_forwarder.heartbeat) follow
every five minutes. If the SIEM shows the JSON undecoded, add a parser for the
body; see below.
Parser
Parse the message body as JSON and read the fields under the key
xplicittrust: the message body in syslog, each element of events[] in a
webhook. The fields are in
Syslog over TLS and the
Event reference. Index on the event creation time,
created_at inside the JSON, when the time of the event matters: after an
outage the forwarder delivers the backlog at once.
Recommended alerts
The Detections page lists the situations worth an alert, with the Wazuh rules and Sentinel queries as models. At the least, alert when a forwarder that sent heartbeats has sent none for four intervals (20 minutes).
Troubleshooting
| What you see | Cause and fix |
|---|---|
| The forwarder shows Failing since … | The console shows the last error. Typical causes: the certificate is not from a publicly trusted CA or does not match the host name, TLS 1.2 is not offered, or the port is not reachable from the internet. |
| Messages arrive as one long line, or are rejected | The framing does not match. Switch between Octet counting (RFC 5425) and Newline-delimited. |
| The JSON is cut off | The receiver or a relay limits the message size; raise it to 64 KB. |
| Some events appear twice | Delivery is at-least-once. Deduplicate on the event id. |
See also
- Concept: Event forwarding
- Guides: Wazuh, Microsoft Sentinel
- Reference: Syslog over TLS, HTTPS Webhook, Detections